Topaz Signature Pad: Difference between revisions

From TraCS Florida Wiki
No edit summary
No edit summary
Line 13: Line 13:
:Bluetooth Units (BT2 & BTB models) - https://www.sigpluspro.com/sigplus-bluetooth.html
:Bluetooth Units (BT2 & BTB models) - https://www.sigpluspro.com/sigplus-bluetooth.html


2. Adjust the TraCS settings.
2. Plug the unit into the computer and log into TraCS.


:The settings in the TopazSignature.ini file may need to be adjusted in order for the unit to work with TraCS.  
3. Follow the steps on [https://www.tracsflorida.org/wiki/index.php?title=How_To_Add_a_Default_Signature this page] to add the user signature.  


:The file is here - C:\ProgramData\TraCS\Settings\DLL Settings
:If it works, no further action is needed unless you would like the settings file pushed out to the agency.   Go to Step 5.


:The two different configurations that may be used.  
:If it does not work, the Topaz settings in TraCS need to be adjusted.   Go to Step 4.


Configuration #1 -
4. Adjust the TraCS settings


This is the default configuration.  
:The settings in the TopazSignature.ini file may need to be adjusted in order for the unit to work with TraCS.  


[Signature]
:The file is here - C:\ProgramData\TraCS\Settings\DLL Settings


'LCDSize 1=4X3 0=1X5 2=1X5 Simple
:The two different configurations that may be used.
LCDSize=1


PromptImage4X3=\Settings\DLL Settings\SignaturePromptScreen.bmp
::Configuration #1 - This is the default configuration.  


ConsentImage4X3=\Settings\DLL Settings\SignaturePromptScreenConsent.bmp
:::[Signature]


PromptImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp
:::'LCDSize 1=4X3 0=1X5 2=1X5 Simple
:::LCDSize=1


ConsentImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp
:::PromptImage4X3=\Settings\DLL Settings\SignaturePromptScreen.bmp


Configuration #2 -
:::ConsentImage4X3=\Settings\DLL Settings\SignaturePromptScreenConsent.bmp


This configuration works with models T-S460-BT2-R, T-S460-HSB-R, and TF-S463-HSNB-R.  
:::PromptImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp


[Signature]
:::ConsentImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp


'LCDSize 1=4X3 0=1X5 2=1X5 Simple
::Configuration #2 - This configuration works with models T-S460-BT2-R, T-S460-HSB-R, and TF-S463-HSNB-R.


LCDSize=2
:::[Signature]


PromptImage4X3=\Settings\DLL Settings\SignaturePromptScreen.bmp
:::'LCDSize 1=4X3 0=1X5 2=1X5 Simple


ConsentImage4X3=\Settings\DLL Settings\SignaturePromptScreenConsent.bmp
:::LCDSize=2


PromptImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp
:::PromptImage4X3=\Settings\DLL Settings\SignaturePromptScreen.bmp


ConsentImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp
:::ConsentImage4X3=\Settings\DLL Settings\SignaturePromptScreenConsent.bmp


3. Plug the unit into the computer and log into TraCS.
:::PromptImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp


4. Follow the steps on [https://www.tracsflorida.org/wiki/index.php?title=How_To_Add_a_Default_Signature this page] to add the user signature.   If it does not work, go back to the settings file and change to the other configuration, save, and then log out of TraCS and back in for the change to take effect.  
:::ConsentImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp


5. Once you know it is working, we can push the settings file from the machine out to the agency.   If you'd like it pushed out, contact us for next steps.
5. Once you know it is working, we can push the settings file from the machine out to the agency.   If you'd like it pushed out, contact us for next steps.

Revision as of 12:08, 22 May 2024

If you would like to use a Topaz Signature pad to add default signatures to TraCS, you must have the Topaz software installed on the machine(s) where you will be doing signatures and you must configure the unit to work with TraCS.

If you need help, contact TraCS Support and we will be happy to assist with the set up.

Steps are as follows:

1. Install the software that matches your Topaz model.

Links to the Topaz Signature Pad installers are below.
Plug-In Units - https://www.sigpluspro.com/index.html
Bluetooth Units (BT2 & BTB models) - https://www.sigpluspro.com/sigplus-bluetooth.html

2. Plug the unit into the computer and log into TraCS.

3. Follow the steps on this page to add the user signature.

If it works, no further action is needed unless you would like the settings file pushed out to the agency.   Go to Step 5.
If it does not work, the Topaz settings in TraCS need to be adjusted.   Go to Step 4.

4. Adjust the TraCS settings

The settings in the TopazSignature.ini file may need to be adjusted in order for the unit to work with TraCS.
The file is here - C:\ProgramData\TraCS\Settings\DLL Settings
The two different configurations that may be used.
Configuration #1 - This is the default configuration.
[Signature]
'LCDSize 1=4X3 0=1X5 2=1X5 Simple
LCDSize=1
PromptImage4X3=\Settings\DLL Settings\SignaturePromptScreen.bmp
ConsentImage4X3=\Settings\DLL Settings\SignaturePromptScreenConsent.bmp
PromptImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp
ConsentImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp
Configuration #2 - This configuration works with models T-S460-BT2-R, T-S460-HSB-R, and TF-S463-HSNB-R.
[Signature]
'LCDSize 1=4X3 0=1X5 2=1X5 Simple
LCDSize=2
PromptImage4X3=\Settings\DLL Settings\SignaturePromptScreen.bmp
ConsentImage4X3=\Settings\DLL Settings\SignaturePromptScreenConsent.bmp
PromptImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp
ConsentImage1X5=\Settings\DLL Settings\SignaturePromptScreen1x5.bmp

5. Once you know it is working, we can push the settings file from the machine out to the agency.   If you'd like it pushed out, contact us for next steps.